¡Ú ÀüÀÚ Àú¿ï
¡Ú ¿Âµµ°è
¡Ú ¾Ð·Â°è
¡Ú À¯·®°è¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¼öÁú | ¼öºÐ | ´çµµ | ¿°µµ°è
°¡½º | ȯ°æ | dz¼Ó°è
Á¶µµ | »öÂ÷ | ¼ÒÀ½ | Áøµ¿°è
±æÀÌ | ÃøÁ¤°ø±¸
ȸÀü | °æµµ°è | °Ë»ç°æ | È®´ë°æ
½ÇÇè±â±¸ | ÀÌÈ­Çбâ±â¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú ±â·Ï | Áö½Ã | º¯È¯ | Á¶Àý°è¡¡¡¡¡¡¡¡
Àü±â °èÃø±â¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú Àü¹® ºê·£µå¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú Ä«½º CAS ÀüÀÚÀú¿ï Àü¹® °ø½Ä ´ë¸®Á¡ A/S ¼­ºñ½º ¼¾ÅÍ
¡Ú ¿ÍÀÌÁî»êÀü WISE °ø½Ä ´ë¸®Á¡
¡Ú Äڴнº KONICS ¿ÀÅä´Ð½º AUTONICS °ø½Ä´ë¸®Á¡
¡Ú Ų½º°è±â KINS °ø½Ä ´ë¸®Á¡
¡Ú ´ºÀνº NEWINS °ø½Ä´ë¸®Á¡¡¡¡¡¡¡
¡Ú ȸ»ç ÁÖ¼Ò | Á¦Á¶»ç¡¡¡¡¡¡¡¡¡¡¡¡
°æ±âµµ ½ÃÈï½Ã °ø´Ü1´ë·Î244 (Á¤¿Õµ¿, ½ÃÈ­À¯Åë»ó°¡ 12µ¿ 123È£)
°æ±âµµ ¾È»ê½Ã ´Ü¿ø±¸ »ê´Ü·Î326 (¿ø°îµ¿, À¯Åë»ó°¡ 17µ¿ 120È£)
°æ±â È­¼º ÆÈź¸é ¼­ÇØ·Î1121¹ø±æ7 ¹ß¾ÈÇö´ë°ø±¸Å¸¿î 502-104
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Ú Àú¿ï¡¤°è·®°èÃø±â Àü¹®
¡Ú Á¦¾î°èÃø±â Àü¹®
¡Ú ½ÇÇè½Ç ÀÌÈ­Çбâ±â Àü¹®
¡Ú ÃøÁ¤°ø±¸ Àü¹®
¡Ú ±¹°¡°øÀαâ°ü °Ë±³Á¤ ´ëÇà¡¡¡¡¡¡¡¡
¡Ú Çѱ¹À¯·®°è°ø¾÷ KOMETER
¡Ú µå¿ÍÀ̾î DWYER¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¹Ì¾²µµ¿ä MITUTOYO¡¡¡¡¡¡¡¡¡¡¡¡¡¡
±Û·Î¹ú·¦ GLOBAL LAB
¹Ì¼º°úÇÐ MISUNG SCIENTIFIC
 
Á¦Ç°¼Ò°³ / ¡Ú ¿Âµµ°è
¡Ú ¿Âµµ°è¡· Ä«Å×°í¸® ºÐ·ù
 
Á¦ Ç° ¸í   A630-A631-A632 : A6300-A6310-A6311-A6320
¸ðµ¨¸í   A630-A631-A632 : A6300-A6310-A6311-A6320
Á¦Á¶È¸»ç   WISE
¹®ÀǸ¦ ¿øÇϽô °í°´²²¼­´Â °í°´¼¾ÅÍ [½ÃÈ­] 031-430-6641 [¾È»ê] 031-508-4900 [È­¼º] 031-352-4509 À¸·Î ÀüÈ­¸¦ Áֽøé Ä£ÀýÇÏ°í ½Å¼ÓÇÏ°Ô »ó´ãÇØ µå¸³´Ï´Ù.
          
 
¡ß Bar stock thermowell with welded connection ¡ß

¡Ü Model : A630-A631-A632 : A6300-A6310-A6311-A6320

¡Ü Service intended:
Temperature sensors or indicating type temperature gauges are not directly inserted into the process pipe- unless these are used to measure the outside temperature of process pipe- instead- these are used with thermowells- by using thermowells- sensors and gauges will not interfere the process line operation- and the users are able to perform the maintenance procedure of the process line more easily. These thermowells can be used in a high steam line or vapor line. These are directly welded onto the socket or pipe so can be a semipermanent. Therefore- the user must carefully deicide its material and specification before welding process is performed.

¡Ü Selection of thermowell :

- Material :
In general- the thermowell material chosen for the installation is governed mainly by the corrosion condition the themowell will face. Recommended material for various services are given in the corrosion table. Occasionally- the material consideration is one of strength rather than corrosion. For example- a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell woule be satisfactory from a corrosion standpoint.

- Insertion :
The distance from the end of the well to the underside of the thread or other connection means (designated as U) is the insertion length.

- Bore size :
Almost any installation uses several types of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant.

- Tapered or straight type :
Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells- thus permitting operation at higher fiuid velocity.

- Option :
Wake frequency calculations in accordance with ASME PTC 19.3 WISE Inc. offers this as an engineering service.