¡ß Sanitary pressure gauge ¡ß
¡Ü Model : P750 : P751-P752-P753-P754-P755-P756
¡Ü Service intended :
P750 series have diaphragm seal to be combined with a pressure gauge. These series are suitable to be used for the situation where corrosive, contaminated, hot, and viscous pressure mediums are present, and it could be used for a chemical, food, beverage, biochemical, and pharmaceutical industry.
¡Ü Nominal diameter : 63, 80 and 100 mm
¡Ü Accuracy :
- 63 and 80 mm : ¡¾1.6% of full scale
- 100 mm : ¡¾1.0% of full scale
¡Ü Pressure range (MPa, kPa, bar) :
- Steady : 75% of full scale (63 mm, 80 mm)
100% of full scale (100 mm)
- Over range protection : 130% of full scale
¡Ü Working pressure :
- Steady : 75% of full scale
- Over range protection : 130% of full scale
¡Ü Working temperature :
- Ambient : -20 ~ 65¡ÆC
- Fluid : Max. 121¡ÆC
¡Ü Temperature effect :
Accuracy at temperature above and below the reference temperature (20¡É) will be effected by approximately ¡¾0.5% per 10¡É of full scale
¡Ü Body : Stainless steel (316SS)
¡Ü Diaphragm :
- Stainless steel (316L SS)
- Electropolished diaphragm
- Ra 12 ~ 20 §
¡Ü System filling :
- USP grade glycerin (99.5% pure)
- Option : Food grade silicone
¡Ü Process connection :
- 316SS
- P751 : 1¨ö" and 2" Nut
- P752 : 1", 1¨ö", 2", clamp connection
- P753 : PF¨ú", PF1", PF1¨ö", male screw
- P754 : Standard and non standard flange
- P755 : Homogenizer
- P756 : Homogenizer flange (95 x 43 x 28)
|