¡Ú ÀüÀÚ Àú¿ï
¡Ú ¿Âµµ°è
¡Ú ¾Ð·Â°è
¡Ú À¯·®°è¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¼öÁú | ¼öºÐ | ´çµµ | ¿°µµ°è
°¡½º | ȯ°æ | dz¼Ó°è
Á¶µµ | »öÂ÷ | ¼ÒÀ½ | Áøµ¿°è
±æÀÌ | ÃøÁ¤°ø±¸
ȸÀü | °æµµ°è | °Ë»ç°æ | È®´ë°æ
½ÇÇè±â±¸ | ÀÌÈ­Çбâ±â¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú ±â·Ï | Áö½Ã | º¯È¯ | Á¶Àý°è¡¡¡¡¡¡¡¡
Àü±â °èÃø±â¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú Àü¹® ºê·£µå¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú Ä«½º CAS ÀüÀÚÀú¿ï Àü¹® °ø½Ä ´ë¸®Á¡ A/S ¼­ºñ½º ¼¾ÅÍ
¡Ú ¿ÍÀÌÁî»êÀü WISE °ø½Ä ´ë¸®Á¡
¡Ú Äڴнº KONICS ¿ÀÅä´Ð½º AUTONICS °ø½Ä´ë¸®Á¡
¡Ú Ų½º°è±â KINS °ø½Ä ´ë¸®Á¡
¡Ú ´ºÀνº NEWINS °ø½Ä´ë¸®Á¡¡¡¡¡¡¡
¡Ú ȸ»ç ÁÖ¼Ò | Á¦Á¶»ç¡¡¡¡¡¡¡¡¡¡¡¡
°æ±âµµ ½ÃÈï½Ã °ø´Ü1´ë·Î244 (Á¤¿Õµ¿, ½ÃÈ­À¯Åë»ó°¡ 12µ¿ 123È£)
°æ±âµµ ¾È»ê½Ã ´Ü¿ø±¸ »ê´Ü·Î326 (¿ø°îµ¿, À¯Åë»ó°¡ 17µ¿ 120È£)
°æ±â È­¼º ÆÈź¸é ¼­ÇØ·Î1121¹ø±æ7 ¹ß¾ÈÇö´ë°ø±¸Å¸¿î 502-104
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Ú Àú¿ï¡¤°è·®°èÃø±â Àü¹®
¡Ú Á¦¾î°èÃø±â Àü¹®
¡Ú ½ÇÇè½Ç ÀÌÈ­Çбâ±â Àü¹®
¡Ú ÃøÁ¤°ø±¸ Àü¹®
¡Ú ±¹°¡°øÀαâ°ü °Ë±³Á¤ ´ëÇà¡¡¡¡¡¡¡¡
¡Ú Çѱ¹À¯·®°è°ø¾÷ KOMETER
¡Ú µå¿ÍÀ̾î DWYER¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¹Ì¾²µµ¿ä MITUTOYO¡¡¡¡¡¡¡¡¡¡¡¡¡¡
±Û·Î¹ú·¦ GLOBAL LAB
¹Ì¼º°úÇÐ MISUNG SCIENTIFIC
 
Á¦Ç°¼Ò°³ / ¡Ú ¿Âµµ°è
¡Ú ¿Âµµ°è¡· Ä«Å×°í¸® ºÐ·ù
 
Á¦ Ç° ¸í   R120 : R121-R122
¸ðµ¨¸í   R120 : R121-R122
Á¦Á¶È¸»ç   WISE
¹®ÀǸ¦ ¿øÇϽô °í°´²²¼­´Â °í°´¼¾ÅÍ [½ÃÈ­] 031-430-6641 [¾È»ê] 031-508-4900 [È­¼º] 031-352-4509 À¸·Î ÀüÈ­¸¦ Áֽøé Ä£ÀýÇÏ°í ½Å¼ÓÇÏ°Ô »ó´ãÇØ µå¸³´Ï´Ù.
          
 
¡ß Sheathed thermocouple ¡ß

¡Ü Model : R120 : R121-R122

¡Ü Service intended :
Sheath type thermocouple generally shares the similar principle of protection tube type thermocouple. However, it has a different construction. It is filled with inorganic insulating material between the thin wire and the metal sheath, and it shares the same body as one. Inside the thin stainless steel pipe, thermocouple element is located, and then stainless pipe is filled with a MgO. Normally, thermocouple is used with a thermowell. The advantages over protection tube types are ; it has a faster response time, it has a broader temperature range (-200 ~ 1,600¡É), longer life, it can be bended to install according to its required installation site condition, a better mechanical strength, and a better internal pressure control.

¡Ü Element type : K,E,J,T,N

¡Ü Tolerances on temperature reading :
- Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
- Special, Standard (ASTM E230 E988 ISA-MC96.1)

¡Ü Head material :
- ALDC (Standard)
- 304SS (Not available compact type)
- 316SS (Not available compact type)

¡Ü Hot junction shape :
- Grounded
- Ungrounded

¡Ü Sheath outer diameters :
- 1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0, 9.5 and 12.7 mm
- Double element is not available for 1.0 and 1.6 mm
- sheath outer diameter







Ä«´Ù·Î±×
¿Âµµ¼¾¼­ »ç¿ëÀÚ ¸Þ´º¾ó - ±¹¹®
»ç¿ëÀÚ ¸Þ´º¾ó - ¿µ¹®
IP ½ÃÇè ¼ºÀû¼­ - R121
IP ½ÃÇè ¼ºÀû¼­ - R121,R122,R221,R222
IP ½ÃÇè ¼ºÀû¼­ - General Spring Load
KCS ¹æÆø ÀÎÁõ¼­
±× ¿Ü Á¦Ç° ÀÎÁõ¼­